Your Ad Here
Your Ad Here Your Ad Here

use this for searching book

Thursday, October 23, 2008

Development and Testing of a Capacitor Probe to Detect Deterioration in Portland Cement Concrete

Type of Document Master's Thesis
Author Diefenderfer, Brian K.
Author's Email Address dief@vt.edu
URN etd-101598-140731
Title Development and Testing of a Capacitor Probe to Detect Deterioration in Portland Cement Concrete
Degree Master of Science
Department Civil Engineering
Advisory Committee
Advisor Name Title
Dr. Imad L. Al-Qadi Committee Chair
Dr. Gerardo W. Flintsch Committee Member
Dr. Sedki M. Riad Committee Member
Keywords

* nondestructive evaluation
* nondestructive testing
* dielectric properties
* infrastructure assessment
* parallel-plate capacitor
* capacitor probe
* PCC

Date of Defense 1998-09-07
Availability unrestricted
Abstract

Portland cement concrete (PCC) structures deteriorate with age and need to be maintained or replaced. Early detection of deterioration in PCC (e.g., alkali-silica reaction, freeze/thaw damage or chloride presence) can lead to significant reductions in maintenance costs. Portland cement concrete can be nondestructively evaluated by electrically characterizing its complex dielectric constant in a laboratory setting. A parallel-plate capacitor operating in the frequency range of 0.1 to 40.1 MHz was developed at Virginia Tech for this purpose. While useful in research, this approach is not practical for field implementation. In this study, a capacitor probe was designed and fabricated to determine the in-situ dielectric properties of PCC over a frequency range of 2.0 to 20.0 MHz. It is modeled after the parallel-plate capacitor in that it consists of two conducting plates with a known separation. The conducting plates are flexible, which allows them to conform to different geometric shapes. Prior to PCC testing, measurements were conducted to determine the validity of such a system by testing specimens possessing known dielectric properties (Teflon). Portland cement concrete specimens were cast (of sufficient size to prevent edge diffraction of the electromagnetic waves) having two different air contents, two void thicknesses, and two void depths (from the specimen's surface). Two specimens were cast for each parameter and their results were averaged. The dielectric properties over curing time were measured for all specimens, using the capacitor probe and the parallel-plate capacitor. The capacitor probe showed a decrease in dielectric constant with increasing curing time and/or air content. In addition to measuring dielectric properties accurately and monitoring the curing process, the capacitor probe was also found to detect the presence and relative depth of air voids, however, determining air void thickness was difficult.

free literature


download

No comments:

Your Ad Here